Yes! We are ready!
For our highest grade S-700, please make a reservation.
It could satisfy with all most concrete test.
As our concrete capping gypsum, it also follows all worldwide standards such as: ASTM C617/AASHTO T 231 5.1.1.
The cubic test of Concrete capping S-700 shows below:
Cubic age when test |
Cubic length mm |
Cubic wide mm |
Maximum strength kgf |
Compression strength kgf/cm2 |
Compression strength Mpa |
Compression strength Psi |
40 mins |
50.25 |
50.36 |
21163 |
846.5 |
84.65 |
12277.44 |
45 mins |
50.31 |
50.50 |
19983 |
786.5 |
78.65 |
11407.22 |
50 mins |
50.28 |
50.13 |
21086 |
843.4 |
84.34 |
12232.48 |
Average strength |
|
|
|
825.5 |
82.6 |
11972.4 |
The average strength and standard deviation of capping gypsum S-700 and ground is shown below:
|
Concrete cylinder test by Capping gypsum S-700 Mpa (Psi) |
Concrete cylinder test by Ground Mpa (Psi) |
Ratio |
Criteria |
Pass/Fail |
The average strength of 15 pics concrete cylinder |
65.87 (9553.1) |
64.33 (9329.8) |
1.024 |
>0.98 Xc |
Pass |
The standard deviation of 15 pics concrete cylinder |
2.9 (420.6) |
3.07 (444.9) |
0.945 |
<1.57 |
Pass |